+86-028-85255257
尊龙凯时人生就是博רҵÑз¢ÖÆÔ죺Polarization Maintaining Filter Coupler£¨fast axis blocked£©,ÉÌÒµ¼¶Polarization Maintaining Filter Coupler£¨fast axis blocked£©,¹¤Òµ¼¶Polarization Maintaining Filter Coupler£¨fast axis blocked£©,Polarization Maintaining Filter Coupler£¨fast axis blocked£©±£Æ«¹âÆ÷¼þ,ÊÇÒ»¸öºÜÊÇרҵµÄPolarization Maintaining Filter Coupler£¨fast axis blocked£©³§¼Ò£¬ÓкܺõÄPolarization Maintaining Filter Coupler£¨fast axis blocked£©¼ÛÇ®¡£尊龙凯时人生就是博Ñб¬·¢²úµÄPolarization Maintaining Filter Coupler£¨fast axis blocked£©ÆÕ±éÓ¦ÓÃÓÚº½Ìì¡¢º½¿Õ¡¢µçÁ¦¡¢Ìú·¡¢Ò½ÁÆ¡¢½»Í¨¡¢Í¨Ñ¶¡¢µÈ¸÷´óÁìÓò¡£
Polarization Maintaining Filter Coupler£¨fast axis blocked£© |
||||||||
Features |
Applications |
|||||||
Low Insertion Loss |
EDFA & Raman Amplifier |
|||||||
High Return Loss |
Fiber Sensor |
|||||||
High Extinction Ratio |
Fiber Optical Instrument |
|||||||
High Reliability |
Power Monitoring System |
|||||||
High Stability |
|
|||||||
Specifications |
||||||||
Parameter |
Unit |
Value |
||||||
Type |
- |
1x2 |
2x2 Type |
|||||
Center Wavelength |
nm |
1310,1550 |
1064 |
1310,1550 |
1064 Center Wavelength nm |
|||
Operating Wavelength Range |
nm |
¡À40 |
¡À20 |
¡À40 |
¡À20 Operating Wavelength Range nm |
|||
Excess Loss |
dB |
0.7 |
0.8 |
1.0 |
1.2 Excess Loss dB |
|||
Uniformity (only for 50/50) |
dB |
0.4 |
0.5 |
0.6 |
0.8 Uniformity dB |
|||
Coupling Ratio |
dB |
01/99~50/50 Coupling Ratio dB |
||||||
Min. Extinction Ratio |
only for F type |
dB |
22 |
22 |
22 |
22 Fast axis Blocked dB |
||
Min.Return Loss |
dB |
50 Min. Return Loss dB |
||||||
Max.Optical Power(CW) |
mW |
300 Max. Optical Power(CW) mW |
||||||
Max.Tensile Load |
N |
5 Max. Tensile Load N |
||||||
Fiber Type |
Tap Port |
- |
SMF-28e, HI1060 or PM Panda Fiber Fiber Type Tap Port2 |
|||||
Port1 & 3 |
- |
PM Panda Fiber Port1 & 3 |
||||||
Operating Temperature |
¡æ |
-5~+70/-40~+85 Operating Temperature ¡æ |
||||||
Storage Temperature |
¡æ |
-40~+85 Storage Temperature ¡æ |
||||||
For device with connector, IL is 0.3dB higher, RL is 5dB lower, ER is 2dB lower; |
||||||||
The default connector key is aligned to slow axis; |
||||||||
For Type 1x2, routing path is 3 to 1,2(tap). For Type 2x2, routing path is 1 to 3, 4(tap), 3 to 1, 2(tap) |
||||||||
Package Dimensions |
||||||||
Ordering Information |
||||||||
PMFC-1111-23345678-9999 |
||||||||
1111 |
-Center wavelength: |
1550=1550nm,1310=1310nm,......,0850=850nm |
||||||
2 |
-Port number: |
1=1x2, 2=2x2 |
||||||
33 |
-Tap ratio: |
01=1%,02=2%,......,05=5%,......, 50=50% |
||||||
4 |
-Axis alignment |
F=Slow axis working Fast axis blocked, B=Both of axis working |
||||||
5 |
-Fiber type for tap port: |
1=PM Panda fiber aligned, 2=smf-28e, 3=hi1060 |
||||||
6 |
-Fiber type for port 1,3: |
1=PM Panda fiber, 2=SMF-28e,3=Hi1060 |
||||||
7 |
-Pigtail type: |
0=250 bare fiber, 1=900um loose tube, 2=2.0mm loose tube, 3=3.0 loose tube |
||||||
8 |
-Fiber length: |
0=0.8m,1=1m |
||||||
9999 |
-Connector type: |
0=FC/UPC,1=FC/APC,2=SC/UPC,3=SC/APC,4=LC/UPC,5=LC/APC |